Silent knight recommends spacing sensors in compliance with nfpa 72. The silent knight sk 300 series is a line of voice evacuation products suitable for use with silent knights model 5204 and 5207 fire controlcommunicators.

Diagram Based Addressable Fire Alarm Control Panel Wiring
Silent knight 5207 wiring diagram. Silent knight security systems b. Addressable fire alarm control panel. 71 using step programming enter step programming mode press followed by the code that has been programmed as code 0 the. Ske 300 series voice evacuation system overview. 151204 1 1 section 1 introduction the model sk 5208 is an 24 volt 10 zone fire alarm control panel expandable up to 30 zones using sk 5217 zone expanders with a digital communicator that meets nfpa 72 requirements. 26092018 26092018 1 comments on silent knight 5207 wiring diagram.
Or or p3 earth ground fault to circuit ground. Silent knight swift instructional manual for wsk heat. Addressable fire alarm control panel. Silent knight swift instructional manual for wsk relay. Type of jack to be installed by the telephone company. For specific information regarding sensor spacing placement and special applications refer to nfpa 72 or the system smoke detector applica tion guide available from silent knight.
See the following sections for details. Function keystrokes system test 0 enter reset alarms or smoke detectors 1 enter clear alarm memory 2 enter reset dialer 3. The following silent knight modules used with the model 5207 panel. For a total expansion of the system to. Sk 2 and sk 4 conventional facp 2 4 zone manual. Model 5207 fire alarm built in touchpad operating instructions these instructions must be framed and displayed next to the model 5207 panel in accordance with nfpa 72 fire code for local protected fire alarm systems.
Compatible modules manufactured by silent knight model what it does 4180 status displayrelay module for remote annunciation of alarm and trouble status information for each zone. In low air flow applications with smooth ceilings space sensors 30 feet apart 91 m. Rj31x warning this device has been verified to comply with fcc rules part 15. The model 5230 remote annunciator is for programming the 5207 panel. Silent knight sk basic commands. 11 system overview figure 11 a.
Operator silence alarms 7 enter user code 7 enter. 5210 zone expander adds 8 zones to the 5207. Silent knight 5207 wiring diagram. You must be in step programming mode also known as mode 27 to program the panel. Operation is subject to the. The sk 5208 is a microprocessor based control panel with integrated ul listed communicator designed for applications requiring smoke detection manual pull stations and sprinkler supervision.