Fmm 1 monitor module class a supervised wiring to the monitored device. Scs 8 fan control module annunciator.

Temperature Sensors For Fire Service Access Elevators Fire
Notifier control module wiring diagram. Addressability allows the fcm 1a to be acti vated either manually or through panel programming on a select zone or area of coverage basis. Fcm 1 module see wiring diagram fig. Notifier cmx 2 addressable control. Install contact closure devices per manufacturers installation instructions. Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit.
Notifiers intelligent addressable control module provides supervised monitoring of wiring to load devices that require an external power supply to operate such as horns strobes or bells. Page 5 wiring diagrams this page. In addition this module is intended for powerlimited wiring only. Any number of ul listed contact closure devices may be used. All wiring shown is supervised and power limited. Some panels support.
Set the address on the module per job drawings. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams. Some panels support this module can be used to replace a cmx 2 mod a ule thatdisconnect power to the control panel before installing the modules. Smaller size fits inside devices or junction boxes. Module polarities are shown in alarm connect modules to listed compatible 32 vdc max. One relay required for each circuit.
Set the address on the module per job drawings. Refer to notifier manual. Is recommended 24 vdc circuit 3 4. This module is intend ed for power limited wiring only. Typicalnotifier system control panel only list available from notifier. Fmm 101 mini monitor module class b supervised wiring to the monitored device.
Some control panels have relay built in and do not require external wiring. Break wire run to provide supervision. Notifier cmx 2 control module wiring diagram division of pittway corporation mmx 1a monitor module cmx 2a refer to the appropriate notifier installation manual for detailed system information. To next control module or end of line relay. All wiring must conform to applicable local codes ordinances and regulations. Refer to the appropriate notifier control panel installation note.
Intelligent addressable control module and relay with built in type identification for onyx series panels. Addressability al lows the fcm to be activated either manually or through. Our notifier cmx 2 addressable control module in new condition comes with a warranty of 90 days and fast shipping via ups. Trol module provides notifier intelligent fire alarm control pan els a circuit for notification appliances horns strobes speakers etc. Fzm 1 zone interface monitor module transmits the status of one zone of 2 wire detectors to the fire alarm control panel. The frm 1a addressable relay.
Fmm 1 connect modules to listed compatible notifier control panels only.