The frm 1 relay control module is intended for use in intelligent two wire systems where the individual address of each module is selected using the built in rotary switches. Addressability allows the fcm 1a to be acti vated either manually or through panel programming on a select zone or area of coverage basis.

Pdf Installation Operation And Programming Manual Yunas
Notifier control module wiring diagram pdf. Our notifier cmx 2 addressable control module in new condition comes with a warranty of 90 days and fast shipping via ups. To next control module or end of line relay. Some panels support this module can be used to replace a cmx 2 mod a ule thatdisconnect power to the control panel before installing the modules. Trol module provides notifier intelligent fire alarm control pan els a circuit for notification appliances horns strobes speakers etc. Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 10. Is recommended 24 vdc circuit 3 4.
15 to 32 vdc. Break wire run to provide supervision. Install module wiring in accordance with the job drawings and. Module does not supervise controlled. Some control panels have relay built in and do not require external wiring. Set the address on the module per job drawings.
Refer to the appropriate notifier control panel installation note. In addition this module is intended for powerlimited wiring only. Addressability al lows the fcm to be activated either manually or through. Notifiers intelligent addressable control module provides supervised monitoring of wiring to load devices that require an external power supply to operate such as horns strobes or bells. Notifier cmx 2 addressable control. Fcm 1 module see wiring diagram fig.
Box and the control module must be placed into the barrier and at tached to the junction box figure 2a. The frm 1a addressable relay. Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. Scs 8 fan control module annunciator. One relay required for each circuit. All wiring must conform to applicable local codes ordinances and regulations.
Typicalnotifier system control panel only list available from notifier. Set the address on the module per job drawings. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. Refer to notifier manual. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams. Module polarities are shown in alarm connect modules to listed compatible 32 vdc max.
This module is intend ed for power limited wiring only. 65 ma led on. Intelligent addressable control module and relay with built in type identification for onyx series panels. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b. Notifier cmx 2 control module wiring diagram division of pittway corporation mmx 1a monitor module cmx 2a refer to the appropriate notifier installation manual for detailed system information. Some panels support.