Ac service tech llc 43619 views. December 20 2013 plant id 9300 2881 this device complies with part 15 of the fcc rules.
10ae2f1 Honeywell 2 Port Valve Wiring Diagram Wiring Resources
Taco zvc406 wiring diagram. Taco zvc403 zone valve control pdf 2010 zvc403 zvc406 zone control wiring conected with system pump wiring installation instructions. Zvc406 6 zone valve control with priority. Use copper wire only. Product number transformer max output dimensions of enclosure number of zones voltage at 24 vac width height depth. No matter the application taco now provides the products to maximize system performance while simplifying both instal lation and service. Taco zone controls wiring guide pages switching relays single zone wiring 2 12 switching relays non exp connected together with priority 3 19.
Matter the application taco now provides the products to maximize system performance while simplifying both instal lation and service. Product number transformer max output dimensions of enclosure number of zones voltage at 24 vac width height depth zvc406 6 with priority 120 vac input 80 va 113 47 1 23. When using alternative wiring diagram wiring instructions must be followed so power originates from the boiler aquastat. Zvc406 exp 6 zone valve control with priority and 2 powerports plug in powerport cards for use with all exp controls. Product number transformer max output dimensions of enclosure number of zones voltage at 24 vac width height depth. Instruction sheet zvc406 exp 4 zone valve control 102 367 supersedes.
Taco zone controls to achieve total system integration. Taco zone valve wiring voltage and water flow tested and provedthe water in the top falls through. Wire recommended for 120 vac connections 14 22 gauge wire for thermo stat connections and 14 22 gauge wire for 24 vac source connections. No matter the application taco now provides the products to maximize system performance while simplify ing both installation and service. Failure to follow this. Wiring connections must be made in accordance with all applicable electrical codes.
March 1 2013 effective. The taco zone controls to achieve total system integra tion. The taco zone controls to achieve total system integra tion. Failure to follow these wiring instructions may result in a secondary source of power. This controller permits setting zone 3 to a priority setting that stops other zones for up to one hour such as to assure providing domestic hot water in an indirect fired water heater. No matter the application taco now provides the products to maximize system performance while simplify ing both installation and service.
120 vac wiring must have a minimum temperature rating of 75c. Taco zone controls wiring guide pages switching relays single zone wiring 2 2. December 20 2013 plant id 9300 2879 instruction sheet zvc406 zone valve control warning. External indicator lights simplified wiring works with 2 3 or 4 wire zone valves compact design fuse protected 100 factory tested. February 1 2013 effective.