The all new gobi ii condensate pump has been completely redesigned retaining all the good download. Allow the gobi to remove the water from the collection tray the pump will stop and the alarm contacts will close.
Condensate Pump Wiring Diagram Si 2052 Sauermann Group
Refco gobi 2 wiring diagram. Change alarm relay to fail safe operation. The majority of mini split evaporator installations do not require a condensate pump because the evaporator pan is drained by gravityrefco universal condensate pumphelp wiring gobi condensate pump 0 thoughts on gobi 2 condensate pump wiring diagram. Connect the orange wire to indoor live. The gobi ii has a massive flow range allowing its use from 6000 btuh 175kw up to 120000 btuh 35 kw. Typical data vrf condenser unit outdoor 100 240vac neutral. Remove air handler cover gobi cover and condensate collection tray.
Wire from indoor live. Identifies pc board or wiring faults on data link circuits led indicators show correct operation dimension. Continue to add water until the sensor is fully submerged the pump will switch to full power and the alarm contacts will open. The all new gobi ii condensate pump has been completely redesigned retaining all the good features you like and upgrading everything else. 2 0 gobi ii combi at full power 60 50 40 30 20 10 0 ve rt ical li ft head pressure m. 5060 hz auto sensing universal power input and will operate with water temperatures from 41 77f 5 25c and ambient air temperatures from 375 104f 3 40c.
Connect the orange wire to indoor live. It may be noisy whilst air is purged from the system. The gobi ii uses a standard 120240vac. Telefon 41 41 919 72 82 industriestrasse 11 telefax 41 41 919 72 83 ch 6285 hitzkirch switzerland info at refcoch wwwrefcoch installation operation and maintenance guide for installation and service engineers gobi condensate pump important. Read this booklet before installation of this product. 319 x 288 x 110 lxwxh part no.
Remove the gobi cover. Half fill the condensate collection tray with clean tap water the pump will start on low power. To use fail safe operation. Benefits of the new refco pump. Easy to use 2 color led indicator lights ensure proper installation and offer diagnostic service assistance. Installation instructions video gobi iisep 16 help wiring gobi condensate pump i am trying to wire a gobi pump to a mitsubishi minisplit head and the head has an s1 s2 and s3.
Change alarm relay to fail safe operation. Re fit the gobi cover. Disconnect all power supplies. Remove the violet wire from indoor live. Allow the gobi to remove the. Coil cleaning do not allow the pump to collect or operate with cleaning chemicals in the system.