Excitation power is derived from a three phase permanent magnet. Mx automatic voltage regulator avr.

Mx321 Wiring Diagram
Mx321 wiring diagram. If instability is present at rated voltage refer to stability adjustment then re adjust voltage if necessary. Fitting and operating refer to generator wiring diagram for connection details tdmx321gb060303 summary of avr controls control function direction volts to adjust generator output voltage clockwise increases output voltage stability to prevent voltage hunting clockwise increase the damping effect. The droop adjustment is normally preset in the works to give 5 voltage droop at full load zero power factors. Fitting and operating refer to generator wiring diagram for connection details. A043y701 issue 2 5 ref. Mx321 automatic voltage regulator avr for cummins 1250kva generators.
Refer to generator wiring diagram for connection details 7. 21 mx321 technical specification. Stamford as540 automatic voltage regulator. 18122018 18122018 3 comments on mx321 voltage regulator wiring diagram. Control function turn potentiometer clockwise to 1 avr volts adjust alternator output voltage increase voltage. Clockwise increases the amount of ct.
Wiring diagram for details. Carefully turn volts control clockwise until rated voltage. Stamford as480 automatic voltage regulator. Stamford mx341 automatic voltage regulator. Signal injected into the avr and increases the droop with lagging power factor cos ø. Tdmx321gb060303 fitting and operating refer to generator wiring diagram for connection details 7.
The droop transformer must be connected in the correct main output terminal for proper operation details are as shown in the machine wiring diagram. With the control fully anti clockwise there is no droop. Stamford mx321 automatic voltage regulator. Mx341 and mx321 avr 18 64 overvoltage de excitation breaker sx421 and mx321 avr 18 641 resetting the breaker 19 65 current limit mx321 avr 19 651 setting procedure 19 66 power factor controller pfc3 20 section 7 service and maintenance 21 71 winding condition 21 711 winding condition assessment 21 712 methods of drying out. Refer to wiring diagram before removing the shorting link and connecting the droop transformer. Carefully turn volts control clockwise until rated voltage is reached.
Mx321 is a three phase sensed automatic voltage regulator and forms part of the excitation system for a brush less generator. Refer to alternator wiring diagram for connection details. Mx321 voltage regulator wiring diagram. Voltage adjustment is now completed. Mx321 automatic voltage regulator avr specification controls and accessories.