Variety of notifier fcm 1 wiring diagram. Fmm 1 connect modules to listed compatible notifier control panels only.

Ford Contour Fan Upgrade
Frm 1 wiring diagram. Surface mounted electrical boxes smb500 are available from notifier. 65 ma led on temperature range. Module polarities are shown in alarm. A wiring diagram is a simplified conventional pictorial representation of an electric circuit. Set the address on the module per job drawings. The box must have a minimum depth of 21 8.
It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools. Fzm 1 zone interface monitor module. Fmm 101 mini monitor module. Typical notification appliance circuit configuration nfpa style y. Connect modules to listed compatible notifier control panels only. 15 to 32 vdc.
Typical fault tolerant notification appliance circuit configuration nfpa style z. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers installation instructions. The frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. When using control modules in. 15 to 32 vdc.
It allows a compatible control panel to switch discrete contacts by code command. Transmits the status of one zone of 2 wire detectors to the fire alarm control panel. Relay module wiring diagram. Class a supervised wiring to the monitored device. Operation each fcm 1a or frm 1a uses one of 159 possible module addresses on a slc loop 99 on clip loops. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b.
4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1. Maximum slc current draw. Secure module to electrical box supplied by installer see figure 2a. Page 1 figure 1. Any number of ul listed contact closure devices may be used. Install module wiring in accordance with the job drawings and appropriate wiring diagrams.
The frm 1 relay control module is intended for use in intelligent two wire systems where the individual address of each module is selected using the built in rotary switches. The frm 1a provides two form c dry contacts that switch together. Page 5 wiring diagrams this page. Smaller size fits inside devices or junction boxes. 15 to 32 vdc maximum current draw. A78 2611 11 a78 2610 08 specifications normal operating voltage.
Module mounting with barrier. All wiring shown is supervised and power limited. The fcm 1a is configured for a single class b style y or class a style z notification appliance circuit. Removing general description rotary switch stop. Class b supervised wiring to the monitored device. 65 ma led on.
32f to 120f 0c to 49c dimensions. Maximum slc current draw. Removing rotary switch stop. All wiring must conform to applicable local codes ordi nances and regulations. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams.