An automatic fire alarm systemtypically made up of smoke detectors heat detectors manual pull stations audible warning. Fire alarm control module wiring diagram wiring diagram is a simplified customary pictorial representation of an electrical circuit.

13 Four Wire Smokes With On Board Relay Introduction To Fire Alarms
Fire alarm control module wiring diagram. 2 firelite slc wiring manual pn 51309r2 3192019 fire alarm emergency communication system limitations while a life safety system may lower insurance rates it is not a substitute for life and property insurance. Siga rel 69 isolator module. Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 10. One relay required for each circuit. It shows the components of the circuit as simplified shapes and the capacity and signal associates together with the devices. Module polarities are shown in alarm connect modules to listed compatible 32 vdc max.
Box and the control module must be placed into the barrier and at tached to the junction box figure 2a. Siga im 70 audio. Fire alarm system is the combination of different components such as smoke detector heat detector carbon monoxide detector multi sensor detector call points sounders bells relay module repeater annunciator fire control panel and other related and optional security devices designed for fire alarm control system. To next control module or end of line relay. Is recommended 24 vdc circuit 3 4. Level 0 means no survivability is required wiring within the esz level 1 3 indicate that attack by fire shall not impair the control and operation of notification appliances outside the esz.
Addressability al lows the fcm to be activated either manually or through. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. Some control panels have relay built in and do not require external wiring. Fcm 1 module see wiring diagram fig. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b. The circuit type is designated with a letter a z.
Break wire run to provide supervision. An esz is a discrete area of a building bounded by smoke or fire barriers in which occupants are intended to relocate or evacuate. Refer to notifier manual. The information shown for each control panel includes wiring diagrams and circuit tables. Fire alarm security access control cctv published by edwards systems technology in conjunction with paige electric co lp.