While system is operating disconnect power to the venter motor. If wmo 1 switch is installed allow vent system to cool.

Field Controls Power Venter System Pvu 300 User Manual Page
Field power venter wiring diagram. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. Swg replacement motor kit instruction manual. The combovent mounts on the outside of the building and pulls the combustion gases from the appliance through the outside wall utilizing 100 negative pressure. Control kits can also control the operation of field draft inducers. Sidewall power venting kit model. After determining the location of the venting system termination point see diagram a cut a square hole through the wall 1 larger than the outer pipe diameter of the power venter.
Block the vent pipe with a noncombustible material. See the chart below to select the proper kit for your application. Wiring diagram for model cas 4mv power vent single 750mv gas appliance combustion air system. Field controls ck 63 venterburner control system for oil systems control kits ck control the operation of swgcv power venters. Swg 4g items included in kit. Wiring instructions wire the venter motor and controls in accordance with the national electrical code manufacturers recommendations andor applicable local codes.
Disconnect the vent pipe between the venter inlet and the appliance outlet. Fields power venter wiring diagram field controls 46457800 user manual fields power venter wiring diagram wiring diagram is a simplified welcome pictorial representation of an electrical circuit. Combo vent is the safest most efficient power venter available today the combovent cv combines the motor blower and vent hood in one complete easy to install unit. Search by combustion air treatment or ventilation. Single wall vent pipe refer to diagram b may be used to join the appliance to the power venter. This equipment is designed to.
Check ground circuit to make certain that the unit has been properly grounded. Cas 4mv ck 81 chimney vent single 750mv gas appliance wiring diagram. Connecting power venter to appliance figure 3 figure 4 diagram a 3. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated. 1 swgii 4hd sidewall power venter. The wiring should be protected by an over current circuit device rated at 15 amperes.
Mount the power venter through the wall keeping the outer pipe centered in the hole. A power venter uses a motorized blower to vent the products of combustion. Search the field controls wring diagram library for all wiring disgrams on field controls products. May require optional delay oil valve for simultaneous burner operation. Installation manual and wiring diagrams for models swg ii 5 swg ii 6 aga and swg 8 sidewall power venter kits. Power venting or sidewall vent is more economical and safer than a chimney vent.
This should open the pressure switch contacts and stop burner operation. It shows the components of the circuit as simplified shapes and the gift and signal associates along with the devices.