Mounting mmx 1a cmx 2a and iso x devices mmx 1a cmx 2a and iso x modules mount directly to 4 inch square electri cal boxes as shown in figure 2a. Notifier nfs manual online.
Preview Notifier Mmx 1 A Monitor Module Cmx 2 A Control
Notifier mmx 1 wiring diagram. Mounting the fcm 1 mounts directly to 4 square electrical boxes see figure 2a. All wiring must conform to applicable local codes ordi. Mounting the frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. 16112018 16112018 3 comments on notifier fcm 1 wiring diagram. Releasing applications c limited energy cable cannot be used to wire a. Fzm 1 has a panel controlled led indicator and can be used to replace mmx 2 modules in existing systems.
The mmx 102e mounts in a standard single gang electrical knock. Notifier nfse manual online. All wiring must conform to applicable local codes ordi. Fmm 1 connect modules to listed compatible notifier control panels only. Compatible notifier system control panels only list available from notifier. Connecting a releasing device to the fcm 1 rel.
Page 5 wiring diagrams this page. The box must have a minimum depth of 218. Surface mounted electrical boxes smb500 are available. The box must have a minimum depth of 21 8. Install contact closure devices per manufacturers installation instructions. The monitored circuit may be wired as an nfpa style b class b or style d class a ini tiating device circuit.
The smb500 may then be installed in a 19 rack assembly using notifier 19 rack mounting adapters. Compatible notifier system control panel list available from noti fier. The box must have a minimum depth of 218. All wiring must conform to applicable local codes ordinances and regulations. Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. Notifiers offers a variety of intelligent monitor modules for diverse applications.
Fzm 1 applications use the fzm 1 to monitor a zone of two wire smoke detectors. This module is intend ed for power limited wiring only. Mmx 1e sem screws with clamping plates for ease of wiring mmx 1e lpcb and vds approved installation the mmx 1e mounts in the notifier multi mount enclosure or an smb500. Set the address on the module per job drawings. Notifier fcm 1 wiring diagram. Surface mounted electrical boxes smb500 are available from notifier.
Connecting a releasing device to a fcm 1 module connecting an. Monitor modules model numbers include the fmm 1 fmm 101 fzm 1 and fdm 1. May also be used to monitor normally open supervisory devices with special. A 39 k ohm end of line resistor pro. When using control modules in nonpower limited applica. All wiring must conform to applicable local codes ordinances and regulations.
Monitor modules supervise a circuit of dry contact input devices such as conventional heat detectors and pull stations or monitor and power a circuit of two wire smoke detectors. The fmm 1a can be used to replace mmx 1a modules in existing systems. Fmm 1a applications use to monitor a zone of four wire smoke detectors manual fire alarm pull stations waterflow devices or other normally open dry contact alarm activation devices. All wiring shown is supervised and power limited. Any number of ul listed contact closure devices may be used.