Fsp 851r photoelectric detection suitable for use with dnrw duct smoke detectors operating temperature. See figure 2 2.
Fsp 851 Photo Electric Smoke Detector Pdf Electrical Wiring
Fsp 851 wiring diagram. Dual leds for 360 visibility. Fsp 851low profile intelligent photoelectric sensor. Wire the sensor base supplied separately per the wiring diagram see figure 1. Im proper connections will prevent a system from responding properly in the event of a fire. Fsp 851 fsp 851t and fapt 851 intelligent photoelectric smoke sensors. Air duct detector sampling tube sampling tube endcap arrow must face into air flow.
Readbag users suggest that dn 60383 a2fm is series intelligent control panels with two the slc wiring manual document 52304. Wiring instructions consult the appropriate detector installation instructions for the applicable wiring diagram. Notifier fsp 851a series intelligent plug in smoke detectors with provided by the slc interface for any notifier intelligent control panel. Designed to sense smoke produced by a range of smouldering combustion sources and with functions such as drift compensation to reduce unwanted alarms. Wiring compartment cover sensor module cover h0569 20 note. In order to set the sensor above address 99 on compatible.
Our solutions will help you determine the best system to meet the needs of your application. Remove power from the communication line before installing sensors. Refer to the control panel technical documentation for compatible ul listed heads with remote test capability. Fsp 851 is a flashscan photoelectric smoke detector compatible with notifier intelligent addressable fire alarm control panel. Notifier is a fire alarm control panels. The rts151key mounts to a single gang box 2 12 minimum depth or directly to the wall or ceiling.
Fsp 851tasame as fsp 851t but with ulc listing. Set the desired address on the sensor address switches see figure 2. In canadian applications the rts151key is intended to be located in the same room as the smoke detector and within 60 feet of. Be color coded to limit wiring mistakes and ease system troubleshooting. A special tool allows maintenance personnel to plug in and remove detectors with out using a ladder. Some panels support extended addressing.
Fsp 851asame as fsp 851 but with ulc listing. Sensor module sold separately. Must be mounted to one of the bases listed below. Page 3 of 3 dn 6935a 122806. Fsp 851 plug in detectors use a separate base to simplify installation service and maintenance. Fsp 851 fsp 851t and fsp 851r.
32f to 120f 0c to 49c rotary address switches for point identification and quick installation. Wire the sensor base supplied separately as shown in the wiring diagram. Low profile intelligent photoelectric. Notifier continuously develops new technologies that improve life safety in buildings worldwide. Fsp 851 is suitable for a wide range of applications. Fsp 851tsame as fsp 851 but includes a built in 135f 57c fixed temperature thermal device.