Effikal Rvgp Ksf Wiring Diagram

Effikal rvgp ksf series flue damper troubleshooting guide see figure on front page of this insert sheet important. Field formerly effikal vent damper wiring harness rvgp ks.

Installation Start Up And Operating Instructions Ama Gas

Installation Start Up And Operating Instructions Ama Gas

Effikal rvgp ksf wiring diagram. Field controls ovd 7 7 automatic oil vent damper 24v 46561707. Checking and adjusting warning. Follow the wiring from the damper and you should find it. If it has a reset on it push it and it just might reset the damper. Field controls 46491600 gma pl vent damper motor assembly plastic base. Keep boiler area clean and free from combustible materials gasoline and other flammable vapors and liquids.

Serial numbers are located on a label on the side of the dampers cap. Wiring errors can cause improper and dangerous operation. Failure to follow this warning could result in explosion fire personal injury or death. This will save half the cost of replacing the entire assembly. It goes without saying its not safe to let kids play with any boiler controls or the thermostat. Field formerly effikal vent damper 46487001 5 inch.

Mine is a effikal model no. Damper must be open before combustion takes place. This is the only motor made for effikal vent dampers. Rvgp pc 7bkf and it has a switch on the back of motor housing. All sizes and models of the rvgp pc have the same motor assembly with black effikal caps and black plastic bases. Field formerly effikal vent damper motor rvgp ks.

The vent damper date code is located on a sticker under the motor assembly cap on the plastic base. 16750 shipping. There is an automatic. If all steps have been tried and damper problems persists contact state water heaters 800 365 8170. Maintenance procedures in addition the maintenance and care of the boiler designated on page 3 and explained on the following pages must be performed to assure maximum boiler. Device must be installed by a qualified installer in compliance with local codes or the national fuel gas code ansi z2231 nfpa 54 or cancga b149 and the national electric code ansi c1 nfpa 70.

Wiring diagram 118119 series controls. Turn off all electrical power to the appliance. Opened for pics your motor is new boxed. When servicing controls all wires must be labeled prior to disconnection. 2 servicing should only be performed by a qualified service technician introduction this service handbook covers the water heater model and series numbers listed on. Field controls 46491600 vent damper motor assembly plastic base this field controls replacement motor with plastic base takes only a few minutes to install.

4950 shipping. It allows you to replace a defective motor without replacing an entire unit. This fits all size rvgp ks vent dampers use your existing assembly wiring harness or universal harness. Test for 24vac between black and orange on damper pc. Effikal rvgp ksf series flue damper troubleshooting guide. When equipped with effikal vent damper model rvgp place service switch in hold damper open position.

Gallery of Effikal Rvgp Ksf Wiring Diagram

State Industries Sbd71120ne Thru Sbd85500ne Effikal Rvgp Ksf
Download Now
State Industries Sbd71120ne Thru Sbd85500ne Effikal Rvgp Ksf
Burnham Corp Nstallation Operating And Service Instructions
Download Now
Burnham Corp Nstallation Operating And Service Instructions
30 Automatic Vent Damper Wiring Diagram Wiring Diagram List
Download Now
30 Automatic Vent Damper Wiring Diagram Wiring Diagram List
John Wood Commercial Atmospheric Vent Ajwsm Owner Manual
Download Now
John Wood Commercial Atmospheric Vent Ajwsm Owner Manual
Models Btr C 120 Thru 500a Water Heaters 1 Models Btr C
Download Now
Models Btr C 120 Thru 500a Water Heaters 1 Models Btr C
Weil Mclain Series 7 Pfg Control Supplement Pdf Download
Download Now
Weil Mclain Series 7 Pfg Control Supplement Pdf Download
Automatic Damper Wiring Diagram Automatic Flue Damper Not
Download Now
Automatic Damper Wiring Diagram Automatic Flue Damper Not
2015 Service Parts Catalog
Download Now
2015 Service Parts Catalog
Vent Damper Motor Assembly Plastic Base
Download Now
Vent Damper Motor Assembly Plastic Base
Models Btr C 120 Thru 500a
Download Now
Models Btr C 120 Thru 500a
Bcg Standard Installation Manual News From American Water
Download Now
Bcg Standard Installation Manual News From American Water
Gas Venting Dampers Gvd Models Field Controls
Download Now
Gas Venting Dampers Gvd Models Field Controls
Burnham Corp Nstallation Operating And Service Instructions
Download Now
Burnham Corp Nstallation Operating And Service Instructions
Effikal Rvgp Ks 6 Bkf Damper Control Huge Inventory
Download Now
Effikal Rvgp Ks 6 Bkf Damper Control Huge Inventory
Commercial Gas Water Heaters Pdf Free Download
Download Now
Commercial Gas Water Heaters Pdf Free Download
State Owner Manual
Download Now
State Owner Manual
Field Controls Gvd 5pl 5 Automatic Vent Damper For 24v Gas Systems Does Not Include Wiring Harness
Download Now
Field Controls Gvd 5pl 5 Automatic Vent Damper For 24v Gas Systems Does Not Include Wiring Harness
Gas Boiler No Heat Call Bad Vent Damper
Download Now
Gas Boiler No Heat Call Bad Vent Damper
A O Smith Btr 120 400 Service Handbook Pdf Download Manualslib
Download Now
A O Smith Btr 120 400 Service Handbook Pdf Download Manualslib